The Storage Battery Branch of Guangzhou Yunshan Automobile Factory

Quality First , Reputation First

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home Products12 Volt Gel Battery

Sealed Valve Regulated Lead Acid Battery NPJ200-12 200 AH 12 Volt Gel Battery

I'm Online Chat Now
Certification
China The Storage Battery Branch of Guangzhou Yunshan Automobile Factory certification
Your choice is our greatest support and encouragement

—— Erick.liu

Sealed Valve Regulated Lead Acid Battery NPJ200-12 200 AH 12 Volt Gel Battery

large.img.alt
small.img.alt

Large Image :  Sealed Valve Regulated Lead Acid Battery NPJ200-12 200 AH 12 Volt Gel Battery Get Best Price

Product Details:
Place of Origin: Guangdong CHINA (Mainland)
Brand Name: PLA
Certification: CE, ISO9001:2004
Model Number: NPJ200-12
Payment & Shipping Terms:
Minimum Order Quantity: 200PCS
Price: Negotiated
Packaging Details: 1PCS/Carton box,Pallets
Delivery Time: within 15-30 days after signing contract and receiving 30% deposit
Payment Terms: T/T, L/C
Supply Ability: 200,000 Pieces/ month
Detailed Product Description
High Light:

gel battery

,

12 volt gel batteries

,

12 volt gel cell battery

 

Sealed Valve Regulated Lead Acid Battery NPJ200-12 200 AH 12 Volt Gel Battery

 

Model Number : NPJ200-12

Nominal Capacity : 200 AH      Voltage : 12v   

Size :522*240*218*242 mm    Weight: 60.0 KG 

Sealed Type : Sealed    

Maintenance Type : Free

 

 

Description:

 

12v 200 Ah VRLA Gel Battery

Special plate design

Long cycle lifetime


 

Features:


1.free maintenance, Long service life
2.No corrosive gas will be generated during normal service
3.Safety for explosion proof
4.Suitable for both cycle use and standby use


Completely sealed and water-free maintenance; no acid gas and environment friendly.

It has adopted colloid electrolyte technology, avoiding density stratification problem of acid solution and eliminating plate corrosion and passivation caused by density stratification.

Applied with German Gel formula, grid alloy and unique plate formula, the battery is performed very well in cycling and recovery from deep discharge, especially in rainy days.

More suitable for using in harsh condition than AGM battery as the rich electrolyte inside of the Gel battery makes it working stable in high temperature or over charge.

Good performance in cold environment and the battery capacity decreases little when using in low temperature.

Little self discharge because of the super-pure material and the low density of the electrolyte, it can be stored over 6 months.

 


 Battery Constructions



1. Positive and negative plates   
Positive and negative plates consist of active mass and a lead-calcium alloy grid structure.

2. Retainer, adjusting plate
Unwoven glass fiber cloth, with a high oxidation and heat resistance, is used to offer superior electrolyte absorption and retaining ability and satisfactory ion conductivity.

3.Safety valve
The safety valve opens when there is an abnormal increase in internal pressure caused by overcharging or misusage. Gas is released from the battery to return the pressure back to normal.

4.Container and covers
Container and covers are made of ABS or PP resin, with superior strength and acid resistance characteristics. The container and covers are sealed to prevent electrolyte and gas leakage.

 

 

Applications:


Cycle use :
1.movable standby power sources
2.Electrical power toys
3.Medical and measuring equipment
4.Power tools,lawn mowers and vacuum cleaners


 

Standby use:


1.UPS
2.Emergency lighting equipment
3.Fire alarm and security systems
4.Telecommunications and power equipment
5.Office computers,microcomputer and other office automation equipment.

Competitive Advantage:

Our product is designed base on JISC standard,do not need to fill into water when Using,  easy to use for user . We are  lead-calcium alloy plate original manufacturer,  we can control the quality and the cost for core of the battery, so we can offer customer high quality battery in attractive price .

 

How to replace battery

 

 

1.Switch off the engine and keep sparks flames cigarettes away from battery at all times before removing the old battery .

Sealed Valve Regulated Lead Acid Battery NPJ200-12 200 AH 12 Volt Gel Battery 0

 

2. Disconnect the negative terminal , first and avoid short-circuit caused by tools ,when removing old battery .

 

Sealed Valve Regulated Lead Acid Battery NPJ200-12 200 AH 12 Volt Gel Battery 1

 

3. Clean corroded parts in tray and cable clamps ,  before installation of new battery

Sealed Valve Regulated Lead Acid Battery NPJ200-12 200 AH 12 Volt Gel Battery 2Sealed Valve Regulated Lead Acid Battery NPJ200-12 200 AH 12 Volt Gel Battery 3

 

4. Clean corroded parts in tray and cable clamps ,  before installation of new battery

 

Sealed Valve Regulated Lead Acid Battery NPJ200-12 200 AH 12 Volt Gel Battery 4Sealed Valve Regulated Lead Acid Battery NPJ200-12 200 AH 12 Volt Gel Battery 5

Contact Details
The Storage Battery Branch of Guangzhou Yunshan Automobile Factory

Contact Person: Mr. Erick.liu

Tel: 8613802545879

Fax: 86-20-86241536-603

Send your inquiry directly to us